| Line 1: | Line 1: | ||
==O2== | |||
*PaO2 - ween O<sub>2</sub> for a goal PaO<sub>2</sub> >60 mmHg) | |||
*FiO2 - ween to < 50% if possible while maintaining adequate PaO2 | |||
*PEEP - refer to ARDsnet protocol to avoid barotrauma | |||
==paCO2== | |||
*Mainly affected by Tidal volume and RR | |||
*VE = minute ventilation (RR x TV) | |||
==pH== | |||
*For every increase or decrease in PaCO<sub>2</sub>, pH changes accordingly by 0.008 | |||
*For every increase or decrease in HCO<sub>3</sub> pH changes accordingly by 0.015 | |||
==See Also== | ==See Also== | ||
Revision as of 20:54, 20 July 2019
O2
- PaO2 - ween O2 for a goal PaO2 >60 mmHg)
- FiO2 - ween to < 50% if possible while maintaining adequate PaO2
- PEEP - refer to ARDsnet protocol to avoid barotrauma
paCO2
- Mainly affected by Tidal volume and RR
- VE = minute ventilation (RR x TV)
pH
- For every increase or decrease in PaCO2, pH changes accordingly by 0.008
- For every increase or decrease in HCO3 pH changes accordingly by 0.015