Adjusting mechanical ventilation settings: Difference between revisions

No edit summary
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
==O2==
==O2==
*PaO2 - ween O<sub>2</sub> for a goal PaO<sub>2</sub> >60 mmHg)
*PaO2 - wean O<sub>2</sub> for a goal PaO<sub>2</sub> >60 mmHg  
*FiO2 - ween to < 50% if possible while maintaining adequate PaO2  
*FiO2 - wean to < 50% if possible while maintaining adequate PaO2  
*PEEP - refer to ARDsnet protocol to avoid barotrauma
*PEEP - refer to [[ARDS|ARDSnet]] protocol to avoid barotrauma


==paCO2==
==paCO2==

Latest revision as of 14:38, 5 January 2022

O2

  • PaO2 - wean O2 for a goal PaO2 >60 mmHg
  • FiO2 - wean to < 50% if possible while maintaining adequate PaO2
  • PEEP - refer to ARDSnet protocol to avoid barotrauma

paCO2

  • Mainly affected by Tidal volume and RR
  • VE = minute ventilation (RR x TV)

pH

  • For every increase or decrease in PaCO2, pH changes accordingly by 0.008
  • For every increase or decrease in HCO3 pH changes accordingly by 0.015

See Also

Mechanical Ventilation Pages

References