*Reposition Airway | *Reposition Airway | ||
*Check correct mask size | *Check correct mask size | ||
*Place OPA | *Place [[OPA]] | ||
*Check for gastric distention | *Check for gastric distention | ||
===Is BVM effective?=== | ===Is BVM effective?=== | ||
| Line 14: | Line 14: | ||
*Monitor and transport | *Monitor and transport | ||
====No==== | ====No==== | ||
*Place endotracheal tube or supraglottic airway | |||
=====Is there effective oxygenation and ventilation?===== | =====Is there effective oxygenation and ventilation?===== | ||
Assess: | Assess: | ||
| Line 31: | Line 30: | ||
*Equipment failure? | *Equipment failure? | ||
Contact online medical control for further instructions | Contact online medical control for further instructions | ||
==References== | |||
<references/> | |||
[[Category: EMS]] | [[Category: EMS]] | ||
Latest revision as of 09:36, 22 March 2026
Airway obstruction?
- Assess for history or concern for foreign body causing airway obstruction
Yes
No
Begin BVM
If BVM is not effective perform the following:
- Reposition Airway
- Check correct mask size
- Place OPA
- Check for gastric distention
Is BVM effective?
Yes
- Monitor and transport
No
- Place endotracheal tube or supraglottic airway
Is there effective oxygenation and ventilation?
Assess:
- ETCO2 Reading
- Misting in tube
- Equal breath sounds
- Direct visualization of the cords if ETT used.
Yes
- Monitor and transport
No
Check airway device
- Tube dislodged?
- Tube obstructed?
- Pneumothorax?
- Equipment failure?
Contact online medical control for further instructions