Harbor:ED supplies A-Z: Difference between revisions
No edit summary |
No edit summary |
||
| Line 3: | Line 3: | ||
** Slit Lamps - AED 1, teaching lamp in RME 10 | ** Slit Lamps - AED 1, teaching lamp in RME 10 | ||
*Main Supply Room A-Z | *Main Supply Room A-Z | ||
**[[File:WikEM1.jpg| | **[[File:WikEM1.jpg|800px]] | ||
**[[File:WikEM2.jpg| | **[[File:WikEM2.jpg|800px]] | ||
**[[File:WikEM3.jpg| | **[[File:WikEM3.jpg|800px]] | ||
**[[File:WikEM4.jpg| | **[[File:WikEM4.jpg|800px]] | ||
*Main Supply Room by cart | *Main Supply Room by cart | ||
*Airway Cart | *Airway Cart | ||
*Central Line Cart | *Central Line Cart | ||
**New Central Line Kit starting 9/2022 | |||
{| class="wikitable" | |||
|+ New Central Line Kit Contents | |||
|- | |||
! !! Old Kits !! New Kit | |||
|- | |||
| Max Sterile barrier (gown and mask, large drape) || No || Yes | |||
|- | |||
| Stat Lock included || No || Yes | |||
|- | |||
| Power Injectable || No || Yes | |||
|- | |||
| 16 cm catheter || No || Yes | |||
|- | |||
| Antimicrobial Impregnated Line || Some || Yes | |||
|- | |||
| Nitinol Wire (will not kink) || No || Yes | |||
|- | |||
| Sterile Saline for Flush || No || Yes | |||
|- | |||
| Dressing || No || Yes | |||
|- | |||
| CHG Pad (instead of Biopath) || No || Yes | |||
|- | |||
| US sterile probe cover and gel || No || Yes | |||
|- | |||
| Chloroprep sticks || 1 || 2 | |||
|} | |||
***Open the saline syringe (remove foil outer wrapping) and drop on your sterile field | |||
***Check outside of kit for lidocaine, you will have to order if not supplied in kit | |||
***May or may not have nitinol wire (nationwide shortage). Nitinol wire is much harder to kink | |||
***New CHG dressing, place pad over insertion site – NO more biopatch | |||
***Has stat locks included | |||
***Sterile US sleeves and sterile gel in kit | |||
***Gown and large drape in kit | |||
***Pull your own correctly sized sterile gloves prior to procedure | |||
***Document CLIP form after placement | |||
***Use everything in the kit, it just goes to the landfill if you don’t use it. (Drapes, extra CHG swab, gown, mask etc..) | |||
***If unused, wipe with disinfectant wipe to save. (Expensive! Please don't waste) | |||
*Ortho/splinting Cart | *Ortho/splinting Cart | ||
*Precipitous Delivery (BOA) Cart | *Precipitous Delivery (BOA) Cart | ||
Latest revision as of 17:58, 12 September 2022
- A-Z listing for entire ED
- Glidescopes - trauma 1-7
- Slit Lamps - AED 1, teaching lamp in RME 10
- Main Supply Room A-Z
- Main Supply Room by cart
- Airway Cart
- Central Line Cart
- New Central Line Kit starting 9/2022
| Old Kits | New Kit | |
|---|---|---|
| Max Sterile barrier (gown and mask, large drape) | No | Yes |
| Stat Lock included | No | Yes |
| Power Injectable | No | Yes |
| 16 cm catheter | No | Yes |
| Antimicrobial Impregnated Line | Some | Yes |
| Nitinol Wire (will not kink) | No | Yes |
| Sterile Saline for Flush | No | Yes |
| Dressing | No | Yes |
| CHG Pad (instead of Biopath) | No | Yes |
| US sterile probe cover and gel | No | Yes |
| Chloroprep sticks | 1 | 2 |
- Open the saline syringe (remove foil outer wrapping) and drop on your sterile field
- Check outside of kit for lidocaine, you will have to order if not supplied in kit
- May or may not have nitinol wire (nationwide shortage). Nitinol wire is much harder to kink
- New CHG dressing, place pad over insertion site – NO more biopatch
- Has stat locks included
- Sterile US sleeves and sterile gel in kit
- Gown and large drape in kit
- Pull your own correctly sized sterile gloves prior to procedure
- Document CLIP form after placement
- Use everything in the kit, it just goes to the landfill if you don’t use it. (Drapes, extra CHG swab, gown, mask etc..)
- If unused, wipe with disinfectant wipe to save. (Expensive! Please don't waste)
- Ortho/splinting Cart
- Precipitous Delivery (BOA) Cart
- RME 1-4 Carts
- Suture Cart
- Triage Hall Cart
- Triage Room Carts